Digital Radiographic Mobile X-ray System- MobileDaRt Evolution MX8 Version c type

Advanced DR Mobile system with new values

Top c type k type v type s type

LITERATURE

Advanced DR Mobile system with new values

MobileDaRt Evolution MX8 Version

Retained Object Confirmation Support Image Processing assisted by AI OPTION

Smart DSI aids the detection of objects retained in the body by enhancing regions of the image that potentially show surgical needles, gauze with radiopaque threads, and other foreign objects.



* Do not rely solely on the imaging processing capabilities of Smart DSI when determining if foreign objects are retained in the patient. Use visual image confirmation, gauze counts, and other methods in reaching a final judgment.
* The AI (artificial intelligence) technology used in Smart DSI is not a self-guided iterative learning-type AI.

Built-in AEC Assistance OPTION

Large Field-of-View to Cover Entire Region

Automatic Exposure Control (AEC) assistance supports the dose reduction for daily hospital rounds.

* This feature is only available for systems configured with CXDI-Elite.

Advanced Image Processing for a Wide Range of Clinical Needs

Scattered X-ray Correction Enables Grid-less Radiography OPTION

The system can be equipped with a function to remove scatter noise and improve image contrast, making it possible to perform exposures without the use of a grid making it easier to handle FPD’s.

Scattered X-ray Correction Enables Grid-less Radiography
Edge Enhancement for Safer Procedures OPTION

For use in surgical operations, the new image processing function helps to confirm the absence of residual instruments like gauze and needles. This is also useful to reconfirm locations for the catheter tip in PICC insertion procedures more clearly.

Edge Enhancement for Safer Procedures

Flat Panel Detectors with Excellent Usability

The lightweight, easy-to-hold design and rounded edges make rounds and bedside imaging more comfortable, minimizing the risk of accidental drops and slips and providing more comfort for the patient. In addition, water resistance and the high load capacity contribute to daily clinical work with peace of mind.

Flat Panel Detectors with Excellent Usability
Top c type k type v type NEW s type